Synchronized PPG and Relative Contact-Load Dataset for a Low-LED-Drive Reflective Platform
Year: 2026
Type: dataset
Abstract: This dataset contains synchronized reflective photoplethysmography (PPG) and relative contact-load measurements collected during a single-participant engineering pilot study evaluating contact-load-dependent PPG signal quality under a low-LED-drive configuration. Red and infrared PPG signals were acquired using a MAX30101 sensor controlled by an nRF52833 microcontroller. Relative contact load was recorded synchronously using an adjacent force-sensitive resistor (FSR) configured as a voltage divider. The optical channels and FSR measurements were sampled at a nominal rate of 100 Hz. The primary experiment consisted of five repeated trials using a prespecified loading sequence comprising low, medium, firm, and medium-return contact states. Each stable loading stage was recorded for approximately 15 s following an adjustment period. The FSR voltage is provided as a setup-specific relative-load proxy and must not be interpreted as calibrated force, interface pressure, strap tension, or wearable tightness. The dataset also includes preliminary control recordings obtained under stable contact, manual pressure modulation, surface-transmitted vibration, contact loss, and side-light conditions. These perturbations were not physically normalized and are intended for qualitative and signal-quality characterization rather than quantitative ranking of artifact severity. Processed outputs include trial-stage summaries, signal-quality metrics, and statistical analysis inputs used to reproduce the principal results reported in the associated manuscript. The dataset is intended to support reproducibility of the reported engineering pilot study and to provide design information for future calibrated, randomized, and multi-participant investigations of contact-aware PPG measurement. Because the data originate from a single human participant, identifying information has been removed. Participant-specific demographic information is limited to information necessary for interpretation of PPG measurements. The participant was a male aged 30–34 years with self-described light skin tone, and measurements were obtained from the left index finger. Fitzpatrick skin phototype and objective pigmentation metrics such as Individual Typology Angle were not formally assessed.
Author: Shang, Yang
Institution: Duke University
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7204529121
