Light reflection-based system for spin measurement of table tennis balls
Year: 2023
Type: conference-abstract
Abstract: INTRODUCTION:Mastering spin is crucial to win a match in table tennis. Spin is one of the keys performance indicators for aplayer, alongside with placement, ball speed, technique and precision. Therefore, it is crucial to measureperformance.However, spin measurement is hard to perform in real match conditions because the speed is high (+/-800rad/s)[1], unless using a high-speed cameras and using image processing algorithms.[2]–[5]We proposed a new low-cost tool for spin measurement based on observation of light reflection on balls. Theproposed system is also able to measure linear speed from a moving object in its field of view (FOV).METHODS:To calibrate accurately our system, comparisons are made with a high-speed camera Miro C210 from Phantom.First experiment is the measure in controlled conditions. The system is used to measure a spinning ballmounted on a motor with constant speed (to ensure the measurement quality of the device).Second experiment is the observation of the spin on real strokes. Strokes were performed by an experiencedsenior player. Services and hits were realized several times with increasing spin given by the player. Balls weredelivered by a ball thrower robot (Amicus Expert from Butterfly).Spin estimation with camera is obtained through frame by frame analysis, while our system is expressing spinby frequency and waveform analysis.RESULTS:Experiment 1 shows a measured spin at 468,7 rad/s (+/-18,8 rad/s).Experiment 2 shows various spin measures, for strokes and services. Services observed spin range goes from174 rad/s to 329.23 rad/s.Strokes performed for topspin forehand shots range goes from 391.75 rad/s to 808.6 rad/s.Strokes performed for topspin backhand shots range goes from 569.8 rad/s to 769 rad/s. Linear speed measuredon forehand & backhand shots is really close from the one measured by camera (+/3.46%).Estimated errorbetween High speed camera and our system is +/-5.6%.CONCLUSION:Although results are consistent with high-speed camera, we observe that the system is light-sensitive. It wouldnot be able to detect in a fully lightened or a fully dark environment or at least with a larger error.We are using bicolored balls which won’t be allowed in real match conditions. Traditional match balls, with theirnatural brands are not reflective enough to get a meaningful output.Nonetheless, the presented system, shows strong results in accordance with a high-speed camera for bothmeasuring linear and rotational speed.[1] P. Blank, B.H. Groh, B.M. Eskofier, in Proceedings of the 2017 ACM International Symposium on WearableComputers, Association For Computing Machinery, New York, NY, USA 2017, 2.[2] T. Tamaki, H. Wang, B. Raytchev, K. Kaneda, Y. Ushiyama, 2012, 1457.[3] J. Tebbe, L. Klamt, Y. Gao, A. Zell, 2020, 9694.[4] C. Liu, Y. Hayakawa, A. Nakashima, SICE Journal of Control, Measurement, and System Integration 2012, 5,233.[5] Y. Zhang, R. Xiong, Y. Zhao, J. Wang, IEEE Transactions on Instrumentation and Measurement 2015, 64, 2280.
Source: HAL
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7205085004
