Dynamic Anatomical Ultrasonography for assessment of bone motion within the postamputation residual lower limb during ambulation: Benchtop scientific validation using 3D-printed phantoms
Year: 2025
Type: conference-paper
Abstract: Introduction The post-amputation residual limb’s health is essentially determined by surgical procedure and the loading regiment applied by the prosthesis. Assessing the effects of loading on residuum health is challenging. There is a need for no-invasive measurements of morphometric changes in residuum tissues during ambulation. Aims Our aim is to develop a portable Dynamic Anatomical Ultrasonography (DAU). This new technique consists of a multi-channel instrument operating in pulse-echo mode and an array of single-element transducers within a 3D-printed holder, that would be attached to the prosthetic socket. Methods A generic hexadecagon water tank and ultrasound transducer holder were created. Utilising 3D-printed phantoms, we performed a series of benchtop experiments to assess: i. Accuracy and linearity of interface depth over the clinically relevant range (Fig.1a). ii. Circumferential uniformity for consistent interface depth. iii. Accuracy of angled interface inclination utilising a twin-layer transducer holder (Fig. 1b). iv. Ability to track the position of a moving interface over a defined period (Fig. 1c). v. Agreement with conventional 3D motion-tracking technique. Analysis consisted of both spreadsheet data and graphical polar plots. Results i. Regression slope of 1.01 (R2=0.99) with -2.08 mm offset attributed to the water-tank wall. ii. Radial interface depth of 40.0+0.0mm for DAU, 39.3+0.0mm for vernier calliper. iii. Inclination values for the maximum and minimum phantom offsets were 6.2x3.2o for digital vernier and 7.0x3.3o for DAU measurements. iv. Radial interface depth of 38.8+0.4mm for DAU, 39.7+0.1mm for vernier calliper. v. Root mean squared error between motion capture and DAU measurements for circular and square profiles were 0.78 mm and 2.14 mm respectively. Discussion We have demonstrated the linearity and uniformity of the DAU technique under static and dynamic benchtop test conditions. Polar plots provide a simple visual representation of static circumferential DAU data, although multiple plots would be required for dynamic data.
Source: Griffith Research Online
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7205121967