From Rough Signal to Polished Spectrum: Absorption Mode Two-dimensional Mass Spectrometry Overview
Year: 2024
Type: conference-abstract
Abstract: Two-dimensional mass spectrometry (2D MS) is a tandem mass spectrometry method where precursor and fragment ions are correlated without isolation. A multifaceted data-independent acquisition technique, 2D MS has found applications from agrochemicals to top-down proteomics with both laser-based and electron-based fragmentation [1]. Developments in signal processing have shaped 2D MS into a fully-fledged analytical method. For narrowband 2D mass spectra with limited precursor m/z ranges, phase-corrected absorption mode, which improves resolving power and signal-to-noise ratios, has enabled the distinction between fragments from histone peptides with m/z 0.006 difference [2]. This study seeks to extract analytical information from all 2D mass spectra with maximum signal-to-noise ratio and resolving power by expanding phase-corrected absorption mode to broadband 2D MS.2D mass spectra of diverse samples (intact proteins, peptide isoform mixtures, protein digests, plant extracts) were recorded on FT-ICR mass spectrometers with magnetic fields between 7-15 T (Bruker Daltonics, Germany) with Gäumann’s pulse sequence and both laser-based and electron-based fragmentation [1]. The frequency range for precursor ions in the vertical dimension ranged from 10 to 1000 kHz (i.e. precursor m/z 5-2000 ranges). All data processing and visualization was performed with the open-source Spectrometry Processing Innovative Kernel (SPIKE) software, developed in 64-bit python language [3]. For all 2D mass spectra, parameter optimization was performed in python notebooks before data processing in batch processing to eliminate limitations in dataset size due to RAM.Phase progression in 2D mass spectra is linear with frequency in the vertical precursor ion dimension and quadratic in the horizontal fragment dimension [4]. For accurate phase correction, different parameters need to be optimized: 3 coefficients for horizontal phase correction, 2 coefficients for vertical phase correction, and the modulation frequency. All parameters are dependent on the experimental conditions determined in the pulse sequence. Phase-corrected absorption mode narrowband 2D mass spectra show that both signal-to-noise ratio and resolving power can be doubled compared to magnitude mode. In addition, phase correction acts as a filter for artefacts from harmonic peaks in 2D mass spectra. Data processing for absorption mode is performed in batch processing to eliminate caps on dataset size imposed by available RAM. We discuss the stability of empirically optimized parameters (modulation frequency, all phase correction coefficients) for automated processing of multiple 2D mass spectra acquired with identical experimental conditions. We establish routines in SPIKE for front-end data processing to produce internally calibrated peaklists for input in data analysis software (e.g. MASCOT for bottom-up proteomics, FAST-MS for top-down proteomics, PyC2MC for petroleomics). We examine disturbances introduced by factors like frequency range and speed of phase accretion as a function of cyclotron frequency (for fragment ion m/z) or of modulation frequency (for precursor ion m/z). We discuss solutions to these issues: asymmetrical apodisation, reconstruction of initial datapoints through autoregressive models, non-uniform sampling, and one-dimensional phase correction.[1] https://doi.org/10.1007/s00249-019-01348-5[2] https://doi.org/10.1021/jasms.2c00319[3] https://arxiv.org/abs/1608.06777[4] https://doi.org/10.3390/molecules26113388
Source: HAL
Language: English
Subfield: Spectroscopy
Field: Chemistry
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7205348306