Development of a transportable neutron imager for localization of radioactive sources
Year: 2024
Type: conference-abstract
Abstract: Detecting radioactive hotspots presents a challenge for the nuclear industry and security applications, such as waste management, decommissioning, radiation protection, and the response to nuclear accidents. In this study, we present a prototype of gamma-neutron imager utilizing a 12 × 12 plastic scintillator (PS) pixel matrix, with each pixel measuring 3.6 mm × 3.6 mm × 3.6 mm and coupled to an ArrayC-30035-144P SiPM from SensL. The light response of each pixel is separated by 0.6 mm of PTFE wall. The electronic readout includes the SiPM, connected to the diode-coupled charge division readout system from AiT. We utilized a rank 7 MURA coded mask, comprising two layers: 1 mm of lead and 1 cm thick polyethylene, with a surface area of 11.4 cm × 11.4 cm. The prototype has a field of view (FoV) of 68°. Additionally, all components were assembled within a polyethylene camera housing measuring 17 cm × 14 cm × 9 cm. We performed Geant4 simulations to determine the optical parameters of the scintillator, explore quenching mechanics, and examine neutron interactions within our scintillator. Additionally, we conducted experiments on the prototype using a proton beam at the Cyrcé facility at IPHC. In this presentation, we will discuss the simulation and experimental results.
Source: HAL
Language: English
Subfield: Radiation
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7205853190