Impact of metal impurities on [18F]fluoride metal capture for radiolabeling purpose: case study on a Gallium chelate
Year: 2026
Type: conference-abstract
Abstract: Positron Emission Tomography (PET) has emerged as a revolutionary medical imaging technique, to help diagnose and guide the treatment of cancer, as well as cardiac and neurological diseases. PET visualizes physiological and pathological processes by tracking a tracer labeled with a positron (β+) emission nuclide. Among these, [18F]fluoride is the most widely used nuclide for clinic applications due to its unique physical properties and wide availability (medical cyclotron production).Conventional radiofluorination methods involve the formation of a C-F bond on the organic backbone of the tracer, which is almost the result of a nucleophilic substitution. This approach requires harsh reaction conditions, which limit its applicability to sensitive tracers such as biomolecules used as specific targeting agents.To address the need for a milder 18F-labeling method, strategies based on the capture of [18F]fluoride by group¬13 metal (aluminum, gallium, indium) chelates have emerged as promising alternatives.[1] Our group recently reported the first chemical system based on a preformed gallium PC2A-based chelate (Figure) enabling radiofluorination by {Ga18F} in water, at room temperature, in 86 % radiochemical yield (RCY).[2] However, the studies we have conducted using this system have occasionally revealed a lack of reproducibility in the RCY values determined by RP-HPLC. Some experimental observations have led us to examine the potential impact of metal contamination during the quality control process, especially since HPLC-column manufacturers had reported the effect of highly electronegative metal ions, such as trivalent aluminum, on ion-exchange capacity, leading to irreversible adsorption of certain analytes (Lewis bases, chelating agents).[3]To investigate this phenomenon, the Ga-F(NODA-MAr) case study (Figure) was considered. We will discuss the impact of certain metal contaminants, such as the aluminum also used in this radiolabeling strategy that involves chelate chemistry and the coordination of fluoride anions to form a ternary species.[1] Chansaenpak, K and al. Chem. Rev. 2016, 45, 954-971.[2] Dioury, F and al. Chem. Eur. J. 2024, 30, e202403358.[3] Ory, D et al. J. Pharm. Biomed. Anal. 2015, 111, 209-214.
Source: HAL
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7205965834