Understanding the influence of external resistance on MFC performance: towards the development of a biosensor for detection of clogging in French vertical flow treatment wetlands

Year: 2025
Type: conference-abstract
Abstract: French Vertical Flow Treatment Wetlands (VF TW) have become a popular technology for treating raw domestic wastewater and performing solids removal and mineralization. However, clogging, solids deposition and biofilm development in the pores of the filter media remain a critical operational challenge, requiring labor-intensive maintenance and potentially disrupting system performance. One promising solution is the use of a Microbial Fuel Cell (MFC)-based biosensor for real-time monitoring of biofilm development. Despite its potential, MFC biosensor technology still needs more in-depth research to explore the design and electrochemical performance in TW environment. This present study evaluated the electrochemical performance of MFCs operating under different external resistances, providing insights for the development of an MFC-based biosensor for clogging detection. Four air-cathode MFCs were inoculated with sludge sample from a French VF TW pilot-scale, installed at the REFLET/INRAE research platform (Craponne, France). The bacteria source was amended with phosphate buffer solution, micronutrients, and sodium acetate. During the start-up phase, the MFCs were operated with an external resistance of 1000 Ω. The system was considered stabilized when the current output remained steady. The MFC performance was then evaluated under two external resistances, tested in duplicate, 100Ω (MFC 1, MFC 2) and 1000Ω (MFC 3, MFC 4). Electrochemical characterization was performed using electrochemical impedance spectroscopy (EIS), and the anodic biofilm structure was analyzed using environmental scanning electron microscopy (E-SEM). The results showed that MFCs operating at 100Ω had the highest current output, with 0.56 mA for MFC1 and 1.11 mA for MFC2. A significant difference was observed between these duplicates (p < 2.2.10-16). This variability may be attributed to connection problems in MFC1, which could have affected electron transfer efficiency. However, the MFCs operating at 1000Ω exhibited a lower current output (0.39 mA), which did not show a statistically significant difference between duplicates (p = 0.8351). These results were expected as a higher external resistance leads to reduced current generation. The current output at 1000Ω was smoother and more stable throughout the operating cycle, which is a desirable feature for long-term monitoring applications. EIS analysis indicated that MFC-1000Ω and MFC-100Ω had similar charge transfer impedance values of 36.33Ω and 33.68Ω, respectively, suggesting comparable electron transfer rates between the electrode and electrolyte. This parameter is related to response and sensitivity of the biosensor. In addition, E-SEM images demonstrated the formation of an anodic biofilm in both external resistor conditions, with a thinner biofilm observed at 1000Ω, which may help mitigate electrode fouling over time. These results highlight the influence of external resistance on the MFC operation, with direct implications for biosensor design. The higher resistance provided a more stable and sufficient signal output, making it a potential external resistor to be applied for long-term clogging monitoring in French VF TWs. Future studies should focus on optimizing electrode and design to align with the French VF TW characteristics. Furthermore, the inclusion unsaturated and intermittent feeding conditions could be interesting strategies to improve sensitivity and reliability of the biosensor.
Source: HAL
Language: English
Open Access status: green
OpenAlex ID: W7206046347
Cites:
Cited by:
Related to: 10