Detection and quantification of SF6 substitute g3 (C4F7N/CO2/O2) byproducts: An experimental and theoretical study

Year: 2025
Type: conference-abstract
Abstract: SF6 is a most prevalent insulation gas widely used in the electrical industry worldwide, declared as one of six (GWP) global warming potential gases in the Kyoto Protocol held in 1999. The search to find alternatives to SF6 was challenging. In this regard, GE VERNOVA researchers proposed an insulation g3 gaseous mixture containing C4F7N/CO2/O2, which proved to be the most promising substitute for SF6. Thermoelectric stress in the circuit breaker decomposes the g3 (C3F7CN/CO2/O2) gas mixture in their corresponding byproducts. The byproducts could be toxic or corrosive in nature and should be identified and quantified with the help of GC-MS technology to maintain operator and instrument safety. For this instance, we developed the GC-MS and FTIR methodologies for the detection as well as quantification of prominent polluted gas molecules, ranging from ppm to % level. Furthermore, density functional theory (DFT) simulation could help us to determine the chemical reaction mechanism and their corresponding absorbed energies during the arcing process. Optimized GC-MS methodology gives us the range of byproducts, including CF4, C2F6, C3F8, CF3CN, C2F5CN, C2F2, (CN)2, CO, COF2, and (C2F7NH2O) amide, present in heavily arced g3 gas sample. Certain molecules, such as SiF(CH3)3, were also detected by the chemical reaction of the GC column with HF. Three standard gas samples containing CF4, C2F6, C3F8, CF3CN, and COF2 molecules in various concentration levels were employed for the calibration. The regression curve of the standard gases was established, and the slight movement of the curve was observed after the 60-day duration. However, the COF2 quantification was not possible by GC-MS due to the strong chemical reaction with column stationary phase and uneven peak area results in consecutive measurements. Thus, COF2 calibration via FTIR technology is established due to the utilization of only a gas cell in the infrared instrument without the interaction of the column with a standard sample for molecule separation. Furthermore, HF cannot be identified by GC-MS technology due to its limitation; therefore, we employ the GASTEC tube that quantifies the HF by color alternation and is also safe to use. Among all, CF4, C2F6, C3F8, CF3CN, C2F5CN, (CN)2, and COF2, HF are the main byproducts occurring during the breaking in a typical circuit breaker with a g3 gaseous mixture.The chemical reaction mechanism of g3 gas with the help of density functional theory is also investigated. Geometry optimization and transition state with one imaginary frequency were simulated by M062X hybrid functional with the combination of 6-311+G(d,p) basis sets, executed in Gaussian 16 software packages. Thermoelectric aging of the g3 gas mixture can open the various complicated channels of chemical reaction; nevertheless, we proposed the two main routes of decomposition coming from C4F7NO and C4F7NO2 intermediates, and a total of 34 and 6 chemical reactions can be obtained by their decomposition. Among the three primary dissociation reactions of the C4F7NO molecule, (R5) C4F7NO  C3F3NO + CF4 and (R6) C4F7NO  C2F5CN + CF2O, bond fission pathways are identified as the thermodynamically favorable route. The energy barrier values for these two reactions are 8.1 kcal mol-1 and 8.0 kcal mol-1, respectively. This paper could deliver a strong experimental and theoretical foundation for understanding the various natures of decomposition of byproducts in a diverse range generated during arcing in a typical circuit breaker.
Source: HAL
Language: English
Open Access status: green
OpenAlex ID: W7206316293
Cites:
Cited by:
Related to: 9