Abstract: Corona-virus disease-19 (COVID-19) is still a huge sociomedical issue and endoscopic procedures can be a risk of infection.While major routes of COVID-19 transmission are droplet spread and contact transmission, aerosol transmission in a closed space also needs to be concerned.Among endoscopic procedures, ERCP-related procedures are considered high-risk for an aerosol generation because they are performed in a closed examination room for a long time.Therefore, infection protection measures are strictly taken for ERCP-related procedures.Infection protection measures including preoperative COVID-19 screening and personal protective equipment(PPE) are now commonly recommended by several guidelines.Meanwhile, there is no established countermeasure against aerosol generation in ERCP-related procedures.It has been reported that the risk of infection due to aerosol generation increases when the CO2 concentration in the environment exceeds 1,000ppm, suggesting insufficient ventilation.We measured CO2 concentration in our examination room during ERCP procedures for 27 cases performed between October 14 and November 1, 2021.We observed that the number of medical staff !6 and the procedure time ! of 23 minutes were associated with insufficient ventilation.In this article, we report this analysis together with the strategy of COVID-19 infection protection measures at Kyorin University Hospital.