Analytical Comparison and Design Evolution of Magnetic-Integrated LCL-Based Filters for Switching Harmonic Suppression in Avionics Power Systems
Year: 2026
Type: article
Abstract: This paper presents a comparative analysis of three magnetic-integrated LCL-derived filter configurations for suppressing high-frequency switching harmonics in avionics power-conversion systems: the integrated LLCL filter, the magnetic-integrated multi-trap LCL filter, and the magnetic-integrated trapped-LCL filter. The high-frequency harmonics considered in this study originate primarily from the pulse-width-modulated (PWM) switching process and can increase current distortion, electrical and magnetic losses, component stress, and the potential for electromagnetic interference in aircraft electrical systems. To enable a consistent comparison, the three filter configurations are evaluated within a unified analytical framework under common system-level operating conditions, while retaining their topology-specific passive and magnetic parameters according to their respective design requirements. The framework distinguishes aggregate total harmonic distortion (THD) from attenuation at targeted switching-frequency bands and incorporates the effects of resonant branches and magnetic coupling. The simulated current THD values of the LLCL, multi-trap LCL, and trapped-LCL filters are 0.82%, 0.84%, and 1.13%, respectively, while their estimated total filter losses are 24.98 W, 59.74 W, and 40.49 W. At the 1 kW operating point, these losses correspond to 2.50%, 5.97%, and 4.05% of rated power, respectively. The results show that the LLCL filter achieves the lowest aggregate THD and estimated loss under the investigated conditions, whereas the multi-trap and trapped-LCL configurations provide additional capability for targeted attenuation of selected switching-frequency components through their resonant structures. Hardware-in-the-loop (HIL) results further support the electrical filtering and dynamic behavior of the investigated concepts. The comparison demonstrates that minimum THD, minimum loss, targeted switching-harmonic attenuation, and magnetic integration are distinct design objectives; therefore, topology selection should be based on the specific requirements and constraints of the intended avionics application.
Source: Aerospace
Language: English
Topic: Power Quality and Harmonics
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,896
Award: G2155630858
OpenAlex ID: W7212298327