Year: 2024
Type: conference-paper
Abstract: This paper examines the influence of input heating rate (Q ̇in) on thermosyphons (TS) characterized by distinct fill ratios (FR) within the range of 0.35 to 0.75. Utilizing the experimental data from these thermosyphons, a comprehensive analysis is conducted to understand the effects of Q ̇in on both pool (RB,P) and film boiling (RB,F) resistances. The study offers detailed insights into the dynamic thermal behaviour of these systems under different operating conditions. Additionally, the paper introduces and validates correlations for pool and film boiling resistance, thereby improving predictive capabilities and aiding in the optimization of these resistances based on the underlying physics.
Source: TSpace (University of Toronto)
Institution: Western University
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7213375573