Work

Physics-Based Joint Reconstruction and Magnetic Field Mapping in Ultra-Low-Field MRI Using Reversed Readout Gradients

Year: 2026
Type: conference-abstract
Abstract: Purpose: To develop a robust method for estimating and correcting the static magnetic field off-resonance ($\Delta B_0$) induced geometric distortions in ultra-low-field (ULF) MRI.Methods: We propose Inverse Readout Consistency (IROC) conjugate phase reconstruction (CPR), a reconstruction-based framework for off-resonance estimation that uses two turbo spin echo (TSE) acquisitions with opposing readout gradient polarities. IROC estimates and compensates for ΔB0 in both acquisitions through CPR by minimizing the discrepancy between their reconstructions. The ΔB0 field is represented using solid spherical harmonics (SSH) and optimized in a multi-resolution framework. The method is evaluated on phantom data acquired at 48 mT, at three positions within the scanner. These positions induced different levels of magnetic field inhomogeneity and gradient nonlinearity, and consequently different degrees of geometric distortion. We compare distortion correction with time-shift based ΔB0 mapping using single pass and iterative CPR and with gradient-reversal based image-domain correction (IDC).Results: IROC achieved the lowest average geometric distortion of the investigated techniques and showed consistent and stable performance across all scanner positions. In contrast, IDC showed substantial instability in the ULF regime, while Iterative CPR consistently outperformed single-pass CPR. IROC outperformed Iterative CPR, the second-best performing method, at every investigated slice position, demonstrating a consistent performance advantage across the entire evaluated object. IROC remained stable with increasingly complex SSH parameterizations and required less than two minutes computation time for SSH orders up to eight, demonstrating computational efficiency and robustness to varying levels of magnetic field inhomogeneity.Conclusion: IROC enables accurate and robust ΔB0 estimation by combining the effect of inverse readout consistency, reconstruction physics and physically constrained field parameterization. The proposed framework provides stable distortion correction for turbo spin echo (TSE) imaging at ultra-low field and offers a promising foundation for any ULF MRI applications involving substantial magnetic field inhomogeneity.
Source: HAL
Language: English
Field: Medicine
Open Access status: green
Award: PIQ
OpenAlex ID: W7213688290
Cites:
Cited by:
Related to: 10