Fluid-intolerance signals as bedside safety limits during early septic shock resuscitation: a multicenter randomized trial
Year: 2026
Type: article
Study designs: Randomized Controlled Trial, Clinical Trial
Abstract: Fluid resuscitation in early septic shock has a narrow therapeutic index. Signals of fluid intolerance are frequently present during early resuscitation, yet current resuscitation strategies do not incorporate them to guide when to limit fluid administration. We evaluated whether integrating fluid-intolerance signals as safety limits could reduce fluid-induced harm without compromising hypoperfusion resolution. In this multicenter, open-label randomized trial in three Chilean ICUs, mechanically ventilated adults with septic shock, persistent hypoperfusion, fluid responsiveness, and at least one high-risk criterion for fluid-induced harm were randomized 1:1 to a fluid-intolerance–limited resuscitation strategy or standard care during a 6-hour protocol window. In the intervention arm, before each bolus, fluid-intolerance signals (lung ultrasound score, VExUS, E/lateral e′, and central venous pressure) were graded as traffic-light: green received a 500-mL bolus, yellow 250 mL, and red no further fluid. Standard care delivered 500-mL boluses while hypoperfusion and fluid responsiveness persisted. The primary outcome was the change in PaO 2 :FiO 2 from baseline to 6 h (ΔPaO 2 :FiO 2 ). Recruitment was discontinued before the planned sample size was reached because continued enrollment was no longer feasible. Among 113 screened patients, 36 of a planned 62 were randomized, and 35 were analyzed (18 standard care, 17 intervention). The intervention group received a lower protocol bolus volume during the 6-hour intervention window than the standard-care group (250 [125–500] vs. 650 [500–1500] mL; between-group difference, − 500 mL [95% CI, − 750 to − 250]). Cumulative fluid exposure from pre-randomization through the end of the protocol window was similar between groups (3375 [2375–3875] vs. 3750 [1875–4851] mL; between-group difference, − 150 mL [95% CI, − 1470 to 1250]). The primary outcome favored the intervention: median ΔPaO 2 :FiO 2 was 40.5 [24.0-58.5] versus − 37.9 [-69.2 to -12.5]; p < 0.001 (between-group median difference + 78.3 points; 95% CI 50.5 to 110.0), and 0–6-hour changes in lactate and capillary refill time did not differ. Because the trial was stopped early, the effect of a fluid-intolerance–limited resuscitation strategy on oxygenation remains uncertain. A larger trial would be needed to determine whether this strategy improves oxygenation. Such a trial appears feasible. ClinicalTrials.gov Identifier NCT06568744, registered August 21, 2024.
Source: Critical Care
Authors: Paulo Melo, Macarena Amthauer, Giorgio Ferri, Roberto Contreras, Juan Pablo Valdivia, César Santis, Vanessa Oviedo, Sofía Valenzuela, Sebastian Morales, Matías Olmos, Roque Basoalto, Carolina S. Goic, Henrique Mendes, Rafael Hortêncio Melo, Philippe Rola, Ross Prager, John Basmaji, Pedro D. Wendel-Garcia, Ricardo Castro, Glenn Hernandez, Eduardo Kattan
Institutions: Pontificia Universidad Católica de Chile, Hospital Santiago Oriente - Dr. Luis Tisne Brousse, Hospital Barros Luco-Trudeau, Agencia Nacional de Investigación y Desarrollo, St George Hospital, Hospital Israelita Albert Einstein, Hôpital Santa Cabrini, Western University, University of Zurich, Vienna General Hospital, University Hospital Zurich, Medical University of Vienna
Language: English
Subfield: Epidemiology
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $4,190
Award: G6073554992
OpenAlex ID: W7214453541
FWCI:
Cites:
Cited by:
Related to: