Balloon pulmonary angioplasty for occlusive lesions of pulmonary artery in Takayasu arteritis: A cohort study
Year: 2026
Type: article
Study design: Observational Study
Abstract: Background Occlusive pulmonary arterial lesions represent a major technical challenge for balloon pulmonary angioplasty (BPA) in patients with Takayasu arteritis–associated pulmonary artery involvement. However, evidence and procedural guidance regarding BPA for occlusive lesions in this population remain limited. Objectives This study aimed to summarize our center experience with BPA for occlusive pulmonary arterial lesions in patients with Takayasu arteritis and to identify potential risk factors associated with restenosis after BPA. Design Retrospective cohort. Methods We retrospectively enrolled patients with Takayasu arteritis who had occlusive pulmonary arterial lesions. Lesions were morphologically categorized as subtotal or total occlusions. Total occlusions were further subclassified as cone-shaped, pouch-like, or ostial occlusions. Results We included 66 patients with Takayasu arteritis, in whom 182 occlusive lesions were identified. In terms of locations, most ostial occlusions (56.52%) located lobar, while other kinds of lesions more common located segmentally. Total occlusions more frequently required guide-extension catheter support than subtotal occlusions (70.21% vs. 40.63%, P <0.001). Hard-tip guidewires were required for revascularization in 53.85% of ostial occlusions, compared with only 3.13% of subtotal occlusions. Lesion-level technical success rates among attempted lesions decreased with increasing lesion complexity: 100% for subtotal occlusions, 96.0% for cone-shaped occlusions, 68.4% for pouch-like occlusions, and 43.8% for ostial occlusions. The corresponding recanalization rates among all identified lesions were 78.69%, 88.9%, 52.04%, and 10.14%, respectively. In exploratory univariable Firth penalized logistic regression, irregular anticoagulation was associated with a higher likelihood of restenosis (OR 8.51, 95% CI 1.39–60.91; P=0.021), whereas baseline hemodynamics were not associated with restenosis. Conclusion The techniques and devices illustrated in this study might guide the BPA performance in addressing occlusive lesions.
Language: English
Subfield: Pulmonary and Respiratory Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,650
Funders: China Postdoctoral Science Foundation, National Science and Technology Major Project, Beijing Municipal Natural Science Foundation, Fuwai Hospital, Chinese Academy of Medical Sciences, National Key Research and Development Program of China, National Key Research and Development Program of China Stem Cell and Translational Research
Awards: G9000386371, G9000386430
OpenAlex ID: W7214579709