Abstract: Hemolysis leads to error laboratory report and more difficult treatment decision. So treatment is delayed and mortality increase. The use of vacuum blood collection tube may increase hemolysis.Objective: To compared rate of hemolysis between vacuum tube and syringe blood collection. Method: We enrolled patients who presented at emergency department of Ratchaburi Hospital between February 1, 2014 and April 30, 2014. The subjects were randomized into 2 groups, group of vacuum blood collection tube or group of syringe. Hemolysis rate was collected and analyzed between both groupsResults: During study period, 300 patients were enrolled. Rate of hemolysis increased in significantly Vacuum blood collection tube group than syringe group. (6.70 vs 0.70 p-value = 0.006) odds ratio 10.64 (95%CI = 10.64-84.21) In vacuum blood collection tube group, using intravenous catheter had more hemolysis rate, but without statistic significance, than straight needle. (p-value = 0.063) Conclusions: Vacuum blood collection tube was increase hemolysis in blood sample significantly than syringe.
Source: Region 4-5 Medical Journal
Author: Srimahadthai, Sirote
Institution: Ratchaburi Hospital
Language: Thai
Subfield: Medical Laboratory Technology
Field: Health Professions
Domain: Health Sciences
Open Access status: diamond