Work

Per- and polyfluoroalkyl substances of emerging concern : Occurrence in laboratory settings

Year: 2026
Type: dissertation
Abstract: Per- and polyfluoroalkyl substances (PFAS) are a diverse group of compounds consisting of a fully or partially fluorinated carbon chain and a variable functional group. They are highly resistant to heat and water and they are extremely persistent, which has led to their widespread use in various applications. Due to their persistence, they have contaminated the environment permanently, and PFAS are also detected in humans. Many PFAS are carcinogenic and immunotoxic and can cause a range of health effects, which has resulted in increasing regulation. Liquid chromatography-mass spectrometry (LC-MS) is the most used approach in PFAS analysis. PFAS are ubiquitous, and many laboratory equipment and analytical instrument components are made of fluoropolymers, which are derived from PFAS precursors. This study was done in collaboration with Bayer’s Extractables & Leachables (E&L) laboratory, which focuses on the analysis of plastic and rubber components and ensures the safety of pharmaceuticals and pharmaceutical packaging. The aim was to determine whether the routine analytics used in E&L can be used in detecting PFAS, how significant the background signal is in the laboratory environment, and whether certain commonly used components release PFAS. In addition, the suitability of the E&L laboratory’s gas chromatography-mass spectrometry (GC-MS) instrumentation for PFAS analysis was evaluated. Using an LC-MS-quadrupole-time-of-flight (QToF) system, all 25 PFAS in the standard mixture were successfully quantified with the routine scan method applied in E&L. The lowest acceptable concentration obtained was 50 ng/L, which is consistent with values reported in the literature for QToF instruments. In addition, PFAS were also successfully extracted from certain plastic and rubber components and identified using the same scan method. The laboratory background signal was clearly visible in the results, and the delay column proved to be an effective solution for it. Thus, the method used was suitable for detecting PFAS in material studies when a delay column was employed. This work offered new insights into the behaviour of PFAS and the sources of contamination and release. This information can be applied for further method development and for future laboratory equipment and material purchases.
Author: Hemmi, Maria
Institution: University of Turku
Language: English
Open Access status: green
OpenAlex ID: W7220784404
Cites: 70
Cited by:
Related to: 10