Work

Assessing effectiveness of groundwater remediation technologies to a coastal aquifer within an urban environment in South Africa

Year: 2022
Type: dissertation
Abstract: The study aimed to assess the effectiveness of Reverse Osmosis technology as an example of ex-situ groundwater remediation technologies.The Cape Flats Aquifer System, an urban coastal system, was used as a case study.Globally, urban groundwater contamination remains a known problem for water users, hence the need to remediate such water.The study argues that effective technologies such as Reverse Osmosis to remediate groundwater contaminants exist.However, the effectiveness of such technologies is not demonstrated to inform the wider application.The question of how effective these technologies are in remediating groundwater contaminants is not fully understood.To answer such a question, the study had three objectives:(1) Determine the concentration levels of selected contaminants, ( 2) Apply a conceptual model of groundwater flow to explain the transport of contaminants, and (3) Demonstrate the effectiveness of Reverse Osmosis technologies in remediating groundwater contaminants.The groundwater remediation plant at the University of the Western Cape, within Cape Flats Aquifer System, was used to assess the effectiveness of Reverse Osmosis in removing contaminants in groundwater.In general, physical, chemical, and biological parameters were studied from various datasets.However, the focus was on Iron (Fe) and Manganese (Mn) as the reported groundwater contaminants in the studied system.Concentration levels of EC, pH, Fe, and Mn were obtained over 3 months from the Quality filtration systems (QFS) water treatment plant.The average concentration levels of EC, pH, Fe, and Mn before treatment were 146.67mS/m; 6.932µ/l [0.00693mg/L] and 26.3 µg/l [0.026mg/L] respectively.The average concentration levels of EC, pH, Fe, and Mn after treatments were as follows: 44.1mS/m; 7.04,32.1µg/l[0.00704mg/L], and 20.92µg/l [0.0209mg/L] respectively.To assess the effectiveness of the Reverse Osmosis [RO] technology, the formula of Removal rate = (1-A/B) *100% was applied where A is the pollutants after treatment and B is the pollutants before remediation.Results showed that 96% of Fe contaminants were removed from the groundwater, and 78% of Mn contaminants were removed from groundwater.Reverse Osmosis technology was found to be 78% to 96% efficient in removing contaminants from the Cape Flats Aquifer.This study concluded that empirical evidence on the effectiveness of ex-situ groundwater remediation technologies such as RO is critical for rolling out new technologies.
Language: English
Open Access status: green
OpenAlex ID: W7220882874
Cites: 89
Cited by: 1
Related to: 10