Safety of a 2 mL/h minimum infusion rate for peripherally inserted central catheters in preterm infants: an exploratory single-center before-after cohort study
Year: 2026
Type: article
Abstract: Peripherally inserted central catheters (PICCs) are essential for delivering parenteral nutrition (PN) to extremely/very low birth weight (ELBW/VLBW) infants. The conventional 3 mL/h minimum infusion rate (MIR) may force PN discontinuation during the transition to enteral feeding, potentially compromising nutritional intake. Evidence supporting specific MIR thresholds is empirical, and lower rates (e.g., 1–2 mL/h) are already used in many units. This was an exploratory, single-center, retrospective before-after cohort evaluation of a practice change. The study compared ELBW/VLBW infants admitted in January-December 2025 (intervention group, 2 mL/h MIR, n = 64) with a historical control group from January-December 2024 (3 mL/h MIR, n = 54). Central PICC tip location was a strict inclusion criterion, and both groups followed unified catheter maintenance protocols. The primary outcome was catheter occlusion, compared with Fisher’s exact test and reported as a risk difference with a 95% confidence interval (CI); Firth’s penalized logistic regression was used as a sensitivity analysis. Secondary outcomes were unplanned removal and catheter-related bloodstream infection (CRBSI). PICC functional idling, the duration of PN delivered via the PICC, and daily weight gain velocity were exploratory process/outcome measures. Baseline characteristics were comparable between the two groups ( P > 0.05). Catheter occlusion incidence did not differ between groups (6.2% vs. 7.4%; risk difference − 1.2% points, 95% CI − 12.0 to + 8.7; P > 0.05). Unplanned removal occurred in 4/64 (6.2%) versus 8/54 (14.8%) catheters ( P = 0.14) and CRBSI in 0/64 (0.0%) versus 2/54 (3.7%) ( P = 0.21). Functional idling was lower in the intervention period (18.8% vs. 57.4%, P < 0.001), the median duration of PN via the PICC was longer (14.0 days, IQR 12.0-16.2, vs. 11.5 days, IQR 7.0–16.0; P = 0.002), and daily weight gain velocity was higher (13.27 ± 1.69 vs. 11.99 ± 1.82 g/kg/d, P < 0.001); these three variables are exploratory and are partly determined by the infusion-rate policy. In this exploratory before-after evaluation, a 2 mL/h MIR was not associated with a statistically detectable increase in catheter occlusion. However, the confidence interval was wide, and the study was not powered to establish safety, equivalence, or non-inferiority. These hypothesis-generating findings support the design of an adequately powered prospective non-inferiority trial.
Source: BMC Pediatrics
Institutions: Shanghai Jiao Tong University, Shanghai Children's Hospital
Language: English
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,090
OpenAlex ID: W7221181003