Symmetry-Breaking-Based Fault Localization in Dual Active Bridge Converters at the Unity-Gain Boundary
Year: 2026
Type: conference-paper
Abstract: Dual active bridge (DAB) converters are critical for high-power applications due to their bidirectional flow and galvanic isolation. However, frequency-domain diagnostic methods for open-circuit faults (OCFs) suffer from a localization ambiguity at the unity-gain boundary$(k=1)$, where primary and secondary side fault signatures become indistinguishable. This paper proposes an enhanced localization strategy based on transient symmetry breaking. When a fault is detected near$k \approx 1$, a controlled adjustment of the voltage ratio and phase shift is introduced to separate overlapping harmonic signatures, restoring fault discriminability without additional sensors or power interruption. Validation in a 7 kW system shows that the proposed method expands the discriminability margin from 0.01 to 0.15 and achieves accurate identification with a latency of approximately 4 ms. The approach provides a cost-effective, software-based solution to improve DAB converter reliability across the full operating range.
Institution: Universitas Gadjah Mada
Language: English
Topic: Advanced DC-DC Converters
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
OpenAlex ID: W7221783047