Work

TEAMx, DECIPHER, Monte Baldo, Particulate matter observations (low-cost sensors), Raw Data, (Institute of Polar Sciences, University of Trento)

Year: 2026
Type: dataset
Abstract: 1. Short Description of the Sensor The ParticulAIR-1 is a low-cost sensor device developed at CNR-ISP (https://particularmatter.org/). It combines an ESP microcontroller, a GPS module, and a Plantower PMS5003 optical particle counter (OPC) that measures PM1.0, PM2.5, and PM10. 1.1 ParticulAIR-1 Specification The sensor operates using a laser light-scattering principle, in which an internal brushless fan draws ambient air past a 650 nm diode laser. Forward-scattered light from suspended particles is detected, counted, and converted to mass concentration through a factory calibration algorithm. The instrument reports particulate matter mass concentrations for PM1, PM2.5, and PM10, while also providing raw particle counts across six particle-size bins (>0.3, >0.5, >1.0, >2.5, >5.0, and >10.0 µm). The effective measurement range for particulate concentrations is approximately 0–500 µg mc, with an upper measurement limit of 1000 µg m⁻³. Reported concentrations have a resolution of 1 µg m⁻³. According to manufacturer specifications, the measurement uncertainty is ±10 µg m⁻³ for concentrations between 0 and 100 µg m⁻³ and ±10% for concentrations between 100 and 500 µg m⁻³. Air is sampled at an approximate flow rate of 0.1 L min⁻¹ using an internal brushless fan. The sensor provides measurements at 1-second intervals when operating in active UART mode; however, in the ParticulAIR-1 implementation, data are typically logged every 10–30 seconds. The device operates at a supply voltage of 5.0 ± 0.5 V DC with a current consumption of up to 100 mA. Physical dimensions are 50 × 38 × 21 mm. The specified operating conditions include temperatures ranging from −10 °C to +60 °C and relative humidity values between 0–99% under non-condensing conditions. Although the PMS5003 sensor itself does not possess an ingress protection (IP) rating, the ParticulAIR-1 enclosure provides basic weather protection suitable for outdoor deployment. Several limitations of the sensor should be considered when interpreting measurements. First, relative humidity can substantially influence reported PM2.5 concentrations because hygroscopic aerosol particles absorb water, increasing particle size and light scattering. Consequently, measurements obtained above approximately 70% relative humidity may exhibit artificially elevated concentrations. Second, the factory calibration assumes spherical particles with a fixed refractive index representative of ammonium sulfate aerosols. Aerosols with different optical properties, such as mineral dust or carbonaceous particles, may therefore lead to systematic underestimation or overestimation of particulate concentrations. Finally, measurements at very low concentrations (<5 µg m⁻³) exhibit reduced signal-to-noise performance; therefore, averaging observations over periods of at least five minutes is recommended for reliable interpretation. 2.1 Measurement Strategy during the Campaign (Low-cost devices) Three devices were deployed during the campaign: one at the base of the target slope (nearby Malga Valfredda), one at the top, on the rooftop of Forte Naole, located on the crest of Monte Baldo, and the third near the mast along the slope (pendio) connecting the Malga and the Forte. 2.1.1 Description of data collection Data was collected manually from the instruments. The sampling rate was set at 20 seconds for all the variables. 2.1.2 Time period covered by the data Forte di Naole: 17/07/2025-10/10/2025 Pendio: 17/07/2025-10/10/2025 Malga Valfredda: 17/07/2025-10/10/2025 2.1.3 Time zone UTC 2.1.4 Physical location Forte di Naole: LAT 45.66405665 N , LON 10.81587334 E , Altitude: 1674 m a.s.l. Pendio: LAT 45,6659871 N, LON 10,82183628 E, Altitude: 1383 m a.s.l. Malga Valfredda LAT 45.6668423 N, LON 10.82414811 E, Altitude: 1322 m a.s.l. 3.2 Description of derived parameters and processing techniques used for low-cost devices 3.2.1 EPA humidity correction Applied using the US EPA recommended formula for Plantower PMS5003 sensors: ```PM2.5_epa = PM2.5_raw / (0.534 × RH/100 − 0.0844 × RH/100² + 0.4956)``` Requires co-located temperature and relative humidity measurements. Not applicable where T/RH is missing (Pendio). 3.2.2 ML model correction (Random Forest) A Random Forest model was trained at each site with a co-located OPC-GRIMM 11-R as ground truth. Predictors: `pm2_5_avg`, `temperature`, `humidity`, `hour`, `weekday`. The best-performing model per site was selected via cross-validation (see `src/R/2_correction-models.R`). Pendio has no OPC reference; malga's trained model is formally assigned but corrections remain fill value due to missing T/RH. | Station | Model type | Training reference ||---------|------------|--------------------|| malga | RF | Palas Fidas 200s (Malga)|| forte | RF | Palas Fidas 200s (Forte)|| pendio | RF (malga) | No reference — corrections are fill_value | 3.3 Description of quality assurance and control procedures None 4. Data Format Low-cost devices: CF-1.8 NetCDF4, `featureType = timeSeries`, indexed ragged array 4.1 Data file structure One file with low-cost sensor measurements (lcs_processed_1h.nc). Time coverage: 2025-07-16 → 2025-10-10 (UTC). Observations are stored in a single flat array ordered **malga → pendio → forte** (indexed ragged array layout). The `stationIndex` variable maps each observation to its station (0 = malga, 1 = pendio, 2 = forte). ```dimensions: station = 3 ; obs = 4 722 (unlimited)key vars: station_name, best_model, lat, lon, elevation # per station time, stationIndex, n_raw # per observation pm2_5_epa_corrected, pm2_5_model_corrected # per observation temperature, humidity # per observation``` 4.3 List of parameters for the low-cost devices | Variable | Dimension | Units | CF standard name | Description ||----------|-----------|-------|------------------|-------------|| `station_name` | station | — | *(cf_role: timeseries_id)* | Station identifier string || `best_model` | station | — | — | Correction model used (format: `<site>_<type>`) || `lat` | station | degrees_north | `latitude` | Station latitude || `lon` | station | degrees_east | `longitude` | Station longitude || `elevation` | station | m | `surface_altitude` | GPS-corrected elevation || `time` | obs | s since 1970-01-01 | `time` | Start of 1-hour averaging window (UTC) || `stationIndex` | obs | — | *(instance_dimension: station)* | Maps each observation to its station (0=malga, 1=pendio, 2=forte) || `n_raw` | obs | 1 | — | Number of raw (~20 s) records averaged into each hourly value || `pm2_5_epa_corrected` | obs | µg m⁻³ | `mass_concentration_of_pm2p5_ambient_aerosol_particles_in_air` | PM2.5 after EPA humidity correction, 1-hour mean || `pm2_5_model_corrected` | obs | µg m⁻³ | `mass_concentration_of_pm2p5_ambient_aerosol_particles_in_air` | PM2.5 after ML model correction, 1-hour mean || `temperature` | obs | °C | `air_temperature` | Air temperature, 1-hour mean || `humidity` | obs | % | `relative_humidity` | Relative humidity, 1-hour mean | Fill value: `−9999` for all floating-point variables. 5. Data Remarks For the low-cost sensor measurements (lcs_processed_1h.nc): - Pendio `pm2_5_epa_corrected` and `pm2_5_model_corrected` are all fill values (−9999); only temperature and humidity are valid at that station.- `n_raw` is a useful data quality indicator: hours with fewer raw records (e.g., < 50) may be less representative.- Values corrected with the ML model should be preferred over the EPA correction for scientific use. For data gaps (Pendio), use raw data from `lcs_raw.nc`.- Source raw file: `data/processed/lcs_raw.nc` (native ~20 s resolution, no corrections). 5.1 Known missing data periods (Palas Fidas 200) 5.2 Software compatibility Any software that can read and handle .csv and/or netcdf data. 5.3 Positioning within the TEAMx programme This dataset, collected during the DECIPHER Monte Baldo 2025 field campaign, was collected within the TEAMx AVTA (Adige Valley Target Area) during the Summer Extensive Operational Period (sEOP).
Language: English
Open Access status: green
OpenAlex ID: W7222939268
Cites:
Cited by:
Related to: 10