Subcutaneous versus transvenous implantable cardioverter-defibrillator therapy: an updated systematic review and meta-analysis
Year: 2026
Type: review
Study designs: Systematic Review, Meta-Analysis
Abstract: Background The subcutaneous implantable cardioverter-defibrillator (S-ICD) avoids intravascular leads but does not provide chronic bradycardia pacing or antitachycardia pacing. We performed an updated systematic review and meta-analysis comparing S-ICD with transvenous ICD therapy, prioritising contemporary randomised evidence and clinically relevant device trade-offs.Methods Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 (PROSPERO: CRD420261328562), PubMed/MEDLINE, Embase and CENTRAL were searched from inception and rerun on 14 September 2026. Randomised evidence was prioritised, with non-randomised evidence analysed separately as supportive. Published time-to-event HRs were retained where available; sparse binary outcomes were analysed without blanket continuity correction, and incompatible endpoints or follow-up horizons were reported separately.Results 23 reports representing 15 study/cohort families were included. In the published Prospective Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy (PRAETORIAN)–Avoid Transvenous Leads in Appropriate Subjects (ATLAS) individual-participant-data analysis Transvenous Leads in Appropriate Subjects (ATLAS) individual-participant-data analysis, S-ICD was associated with a higher hazard of first inappropriate shock (HR 1.61, 95% CI 1.06 to 2.45). Trial-level analysis also showed a higher hazard of first appropriate shock (HR 1.54, 95% CI 1.14 to 2.09), although this finding was sensitive to the uncertainty method. Conversely, randomised evidence showed fewer lead-related complications with S-ICD in PRAETORIAN (HR 0.24, 95% CI 0.10 to 0.54) and fewer major lead-related perioperative complications in ATLAS (risk difference −4.4 percentage points, 95% CI −6.9 to −1.9). The two-trial all-cause mortality estimate was imprecise (HR 1.22, 95% CI 0.89 to 1.66). Infection, pneumothorax and tamponade outcomes were sparse and definition-dependent. PRAETORIAN-Extended Long-Term Follow-Up (XL) provided supportive extended follow-up but was not treated as an independent trial.Conclusions Randomised evidence suggests fewer lead-related and invasive device complications with S-ICD but a higher hazard of first inappropriate shock. First-appropriate-shock inference was method-sensitive, while mortality and rare-event comparisons remained uncertain. Device selection should therefore consider pacing and antitachycardia-pacing requirements, future procedures, infection severity and patient preferences without inferring equivalence from non-significant results.PROSPERO registration number CRD420261328562.
Source: Open Heart
Institutions: Queen Mary University of London, Queen's University Belfast, Royal Blackburn Teaching Hospital, East Lancashire Hospitals NHS Trust, Blackpool Victoria Hospital, Copenhagen University Hospital, Universitätsklinikum des Saarlandes, University of Leicester, University Hospitals of Leicester NHS Trust, National Institute for Health and Care Research, NIHR Leicester Biomedical Research Centre
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,391
Awards: G2154985756, Development of a successful novel technology for sudden cardiac death risk stratification for clinical use - LifeMap, G5331436775, G6005678962, G7636050144, G7816089160, G7953852530, LifeMap – Quality-assurance User-focussed Evaluation of Safety and Tolerability (LifeMap-QUEST) : developing LifeMap-Vest and LifeMap-Compute for exercise assessment with optimised digital ECG recording for sudden death risk stratification, G8470069120, G8961570727
OpenAlex ID: W7223007805