Emergent Re‐Do Open Aortic Valvular Repair and Foreign Body Retrieval During TAVR: A Case Report
Year: 2026
Type: article
Study design: Case Report
Abstract: A 73-year-old man presented for a transcatheter aortic valve replacement after prosthetic aortic valve dysfunction. During the case, the transvenous pacer lost capture, causing the new prosthetic valve to embolize to the ascending aorta. This case details the intraoperative management throughout the valve deployment, attempted retrieval, and subsequent emergent redo open aortic valve repair with foreign body removal. Complications and considerations of a redo open chest, vasoplegia, cardiopulmonary bypass, aortic dissection, right ventricular failure, heart block, and prosthetic valve embolization are discussed.
Source: Case Reports in Anesthesiology
DOI: 10.1155/cria/1207682
Institutions: Cleveland Clinic, Outcomes Research Consortium
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $790
OpenAlex ID: W7225104453
