Work

Recurrent sequencing artifacts at known variant positions: Illumina NovaSeq X + Agilent SureSelect Human All Exon V8

Year: 2026
Type: dataset
Abstract: Laboratorio Aclimu, Genomics Unit, Buenos Aires, Argentina. Version 2.0, November 2026. Per-allele list and exome-wide catalog of recurrent sequencing artifacts observed on the Illumina NovaSeq X at clinically interpreted positions, with a read-level check script and an offline lookup page. These artifacts can appear as variants at ClinVar pathogenic/likely pathogenic positions and canonical splice sites, with apparent allele fractions of up to 0.42. They are supported by reads on one strand only, mostly in the lowest base-quality bin, and present in only one of two overlapping mates. Files novaseqx_v8_artifacts_v1.1.tsv: 1,633 single-nucleotide alleles at ClinVar pathogenic/likely pathogenic positions (release 2026-10-04) and canonical splice positions (MANE Select v1.5, ±1 and ±2) that met the artifact criterion in at least 3 of 17 clinical exomes captured with Agilent SureSelect Human All Exon V8 and sequenced on four NovaSeq X instruments (18 flow cells). Seven exomes from other Illumina instruments served as controls. Annotations include ClinVar, gnomAD v4.1, GIAB v3.6 stratifications and the GIAB v4.2.1 HG002 benchmark. novaseqx_exome_wide_catalog.tsv: 77,356 recurrent artifact-like alleles across the capture region, 72,026 of them seen only in NovaSeq X exomes. nsx_artifact_check.py: classifies each listed allele in a BAM or CRAM file as artifact, likely_real or review, from strand distribution, base-quality bin and agreement between overlapping mates, and optionally annotates a VCF. lookup_page.html: offline search by gene, HGVS or position, and VCF check in the browser. Artifact criterion At least 3 alternate reads, at least 80% of them in the lowest informative base-quality bin of the run, no more than 10% on the minority strand, and no more than 2 with base quality of 20 or higher. Coordinates are GRCh38 (no-alt analysis set). Interpretation A listed allele can be a true variant in a given patient. The list is meant to prompt review of the reads and orthogonal confirmation before reporting, not automatic exclusion. NovaSeq X control software 1.2 labels the lowest informative quality bin as 12, and versions 1.3 and 1.4 label it as 9, which places these bases on either side of the default minimum base quality (10) of common variant callers. Changes from version 1.0 Sites are selected in the 17 NovaSeq X exomes only, with the other 7 exomes reported as platform controls; all alternate alleles are evaluated at each site; HGVS descriptions follow the transcript strand. The exome-wide catalog, the read-level check and the lookup page were added. Links Source code and online lookup page: https://github.com/Laboratorio-Aclimu/novaseqx-artifacts and https://laboratorio-aclimu.github.io/novaseqx-artifacts/ Contact: [email protected] · https://laboratorioaclimu.com.ar License: data under CC BY 4.0; code under the MIT License.
Language: English
Subfield: Genetics
Open Access status: green
OpenAlex ID: W7225261048
Cites:
Cited by:
Related to: 4