Work

SnS-modified platinum electrode for electrocatalytic hydrazine oxidation: mechanistic insights and electrochemical sensing

Year: 2026
Type: article
Abstract: ) of 0.30-0.32. Differential pulse voltammetry enabled HZ determination over two linear concentration ranges of 5-35 µM and 50-3500 µM, with a limit of detection of 2.68 µM and a limit of quantification of 8.13 µM. The sensor further exhibited good operational stability, reproducibility, selectivity against common interfering species, and satisfactory recoveries of 81.0-99.3% for simulated industrial water samples. These results demonstrate that the Pt/SnS-modified electrode is a prospective electrochemical sensing platform for HZ detection, while the mechanistic electrochemical studies provide fundamental insight into its potent electrocatalytic performance.
Source: RSC Advances
Language: English
Field: Chemistry
Open Access status: gold
Estimated APC paid: $1,042
OpenAlex ID: W7225383540
FWCI:
Cites: 60
Cited by:
Related to: 10