Year: 2026
Type: dissertation
Abstract: This thesis investigates a controlled, low-cost framework for detecting and localizing fresh and dried saliva residues using UV-C fluorescence imaging. Surfaces are illuminated using a 265 nm UV-C LED panel, while fluorescence within the 320–380 nm band is captured using a modified consumer-grade camera. Supervised Gaussian classification and condition-specific unsupervised Gaussian Mixture Models (GMMs) are evaluated for foreground–background segmentation. Under controlled indoor conditions, the unsupervised GMM achieved an average accuracy of 96.8% on balanced test sets. The results demonstrate the feasibility of low-cost fluorescence-based contamination detection and its potential integration into autonomous disinfection robots for more targeted and efficient cleaning. Key limitations include optical calibration and sensitivity to outdoor illumination. Future work includes improved optics, larger datasets, more robust detection methods, and integration of the system into a fully autonomous detection–disinfection pipeline.
Author: Akhavan, Mohammad
Institution: York University
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7225545589