Work

Knee Arthroplasty Navigation System based on Spatial Augmented Reality

Year: 2026
Type: dissertation
Abstract: Total knee arthroplasty (TKA) is among the most frequently performed orthopaedic procedures worldwide, yet a notable proportion of patients experience persistent post-operative dissatisfaction, often stemming from suboptimal implant alignment.While robotic-assisted surgical systems significantly enhance resection accuracy and component positioning, their widespread adoption remains constrained by prohibitive capital costs, substantial operating room footprint, and added workflow complexity.Spatial augmented reality (SAR) presents a compelling alternative capable of superimposing navigational cues directly onto the patient anatomy without requiring bulky robotic arms or cumbersome head-mounted displays.This work presents the design, implementation, and benchtop experimental validation of a markerless SAR navigation framework for distal femoral resection in TKA.A dedicated surgical planning application was developed to define the patient-specific resection parameters and determine the target placement and orientation of the distal cutting guide based on pre-operative Computed Tomography (CT) models.The system couples an Ensenso N36 stereo camera with a digital projector, calibrated using structured light patterns to establish direct correspondence between projector pixel space and three-dimensional (3D) physical coordinates.Intraoperatively, dense point clouds acquired from the exposed femoral surface are registered to patient-specific models segmented from pre-operative CT scans using coarse-to-fine point cloud registration algorithms.Through this calibrated spatial transformation, the system projects the target position and orientation of the distal femoral cutting guide into the surgical field in real time, designed to visually align with the upper surface of the physical guide once it achieves its planned surgical pose.The framework was experimentally validated on 3D-printed femoral phantoms across calibration, surface registration, and physical guide positioning.Projector-camera calibration verified accurate closed-loop optical overlay, while the multi-stage registration achieved sub-millimeter inlier root-mean-square error (RMSE) between 0.34 mm and 0.56 mm across full and partially occluded bone surfaces.In physical positioning trials, the system yielded an overall relative positioning mean absolute error (MAE) of 3.88 ± 3.46 mm and an angular MAE of 4.91 ± 3.85 • .While further mechanical and algorithmic refinements are needed to meet strict surgical tolerances, these benchtop results highlight the viability of markerless SAR as a cost-effective, space-efficient alternative to conventional instrumentation and robotic systems.
Language: English
Open Access status: green
OpenAlex ID: W7225600736
Cites: 73
Cited by:
Related to: 10