Work

A Timber Footbridge for a 15-Metre Rural Crossing: Member Sizing, Honest Live Load, and the Span Where the Design Stops Working

Year: 2026
Type: preprint
Abstract: A 15 m locally sawn timber footbridge is sized from beam mechanics. Deflection, not bending strength, governs: 18 people at the span/250 limit, and the same section stops working at about 17 m.
Language: English
Open Access status: green
OpenAlex ID: W7225730632
Cites:
Cited by:
Related to: