Continuous Rhythm Monitoring and CIED Use in Patients Undergoing Transcatheter Tricuspid Valve Replacement
Year: 2026
Type: article
Study design: Observational Study
Abstract: The EVOQUE system was the first transcatheter tricuspid valve replacement (TTVR) system to obtain European Conformity mark and Food and Drug Administration approval for the treatment of severe symptomatic tricuspid regurgitation and has demonstrated improvements in quality of life and functional capacity compared with medical therapy. 1 However, conduction disturbances and the need for cardiac implantable electronic device (CIED) implantation remain important postprocedural concerns.In TRISCEND I and II, new CIED implantation in pacemaker-naive patients occurred in 13.3% and 27.8%, respectively.1,2 European registry data, including all approved and nonapproved systems, similarly reported high-grade atrioventricular block (HAVB) in 9.5% to 13.5% of patients, with most events occurring during index hospitalization.3,4 Previous trials have primarily reported new CIED implantations rather than systematically assessing HAVB.This may underestimate paroxysmal HAVB and new HAVB in patients with pre-existing devices, in whom it may manifest only as an increase in ventricular pacing (Vp) burden.We therefore assessed acute and delayed HAVB and pacing burden after EVOQUE TTVR using continuous rhythm monitoring with implantable cardiac monitor (ICM) and systematic analysis of CIED interrogations.This retrospective, single-center observational study used prospectively collected data from the Bern TTVR registry.Consecutive patients undergoing EVOQUE TTVR at Bern University Hospital between June 2021 and May 2025 were considered.The study was approved by the local ethics committee, all procedures complied with the Declaration of Helsinki, and patients provided written informed consent.Patients were eligible if they had a pre-existing CIED, received a new CIED for HAVB during the index hospitalization, or underwent ICM implantation.ICM was offered to all CIED-naive patients as part of routine postprocedural care.Patients with known HAVB and >95% Vp at baseline, patients without postdischarge CIED interrogation, and patients declining ICM were excluded.In-hospital monitoring comprised continuous telemetry and daily electrocardiograms.ICMs were programmed to detect pauses >3 seconds or heart What is the clinical question being addressed?When does high-grade atrioventricular block occur after transcatheter tricuspid valve replacement?What is the main finding?High-grade atrioventricular block occurred in 21% of patients, with all events occurring within 7 days after transcatheter tricuspid valve replacement.No delayed high-grade atrioventricular block was detected during long-term rhythm monitoring.
Source: JACC Advances
Institutions: University of Bern, University Hospital of Bern
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,936
OpenAlex ID: W7225870845