Year: 2026
Type: article
Abstract: The study presents a static dual-channel wind catcher designed to simultaneously supply fresh air and remove exhaust air without moving components. Analysis of existing wind catcher designs showed that most solutions focus primarily on air supply and provide limited separation of supply and exhaust flows. The proposed “pipe-in-pipe” configuration was developed based on an analysis of ventilation grille and deflector calculation methods, equal inlet and outlet cross-sectional areas, and two-dimensional numerical modelling using Energy2D. Numerical and experimental investigations confirmed the functionality of the proposed design and revealed an interdependent relationship between channel dimensions and wind catcher height. An empirical linear relationship was derived to determine the optimal channel diameter ratio depending on wind catcher height. The proposed solution can be applied in new construction and building renovation using existing ventilation ducts, reducing reliance on mechanical ventilation.
Source: Theory and Building Practice
Institution: Lviv Polytechnic National University
Language: English
Topic: Wind and Air Flow Studies
Subfield: Environmental Engineering
Field: Environmental Science
Domain: Physical Sciences
Open Access status: bronze
OpenAlex ID: W7225884560