A Functional-Integrated Knee Device for Distal Perception and Energy Harvesting in Phase-Synchronized Hip Exoskeleton Control

Year: 2026
Type: article
Abstract: Lightweight hip exoskeletons typically rely on proximal sensing, which limits access to distal lower-limb kinematics and may compromise gait phase synchronization during dynamic locomotion. Adding dedicated distal encoders can improve perception but increases system mass, wiring complexity, and power consumption. To address this trade-off, this paper presents a functionally integrated knee device that combines passive magnetic-strain motion sensing with mechanical energy harvesting to provide knee kinematic information for hip exoskeleton gait phase estimation and explore harvested-energy supply for the local sensing node. The knee device employs a unidirectional pawl-ratchet planetary transmission to harvest mechanical energy during knee extension, achieving an electrical power output of up to 0.378 W. Meanwhile, a passive magnetic-strain sensing array converts knee rotation into high-frequency electrical signals without active electromagnetic excitation. A dual-head 1D-CNN-LSTM network is developed to simultaneously classify locomotion modes and reconstruct continuous knee joint trajectories from 1000 Hz strain signals. The network achieves an overall locomotion classification accuracy of 99.72%, with a trajectory reconstruction MAE of 3.2989°, RMSE of 4.1664°, and R2 of 0.9801 on the independent test dataset covering level walking and running at speeds of 1–4 m/s and stair ascent. The reconstructed knee kinematics are further fused with hip motor encoder feedback to drive a speed-adaptive finite state machine for real-time stance/swing phase estimation. Compared with plantar-pressure-based reference events, the mean phase switching errors remain within 0.36% of the gait cycle for swing-to-stance transitions and 2.07% of the gait cycle for stance-to-swing transitions across locomotion speeds of 1–4 m/s. The observed phase advance at the stance-to-swing transition also indicates the potential of the proposed timing strategy to compensate for actuator response latency. These results demonstrate that functionally integrating passive distal perception with energy harvesting can provide reliable kinematic information for phase-synchronized hip exoskeleton control while reducing the need for dedicated distal sensing hardware.
Source: Sensors
Language: English
Open Access status: gold
Estimated APC paid: $3,137
OpenAlex ID: W7225887516
FWCI:
Cites: 24
Cited by:
Related to: 10