Work

Reduced-Port Robotic Living Donor Nephrectomy Using the da Vinci Xi Platform: A Comparative Cohort Study of SP+1 RDN, Multi-port Robotic, and Laparoendoscopic Single-Site Techniques

Year: 2026
Type: preprint
Study design: Observational Study
Abstract: Background Living donor nephrectomy is performed in healthy individuals and therefore demands a particularly high safety threshold. Robotic donor nephrectomy may improve visualization, dexterity, and ergonomics, while reduced-port approaches seek to decrease abdominal wall trauma. Dedicated da Vinci SP platforms enable true single-port robotic surgery but are not universally available. We evaluated a single-port-plus-one (SP + 1 RDN) configuration performed with the conventional da Vinci Xi platform and compared it with laparoendoscopic single-site donor nephrectomy (LESS-DN) and conventional multi-port robotic donor nephrectomy (RDN). Methods This retrospective single-centre cohort included 808 living kidney donors in a prospectively maintained institutional database. Only 3 surgical techniques were included: 59 Xi SP + 1 RDN, 706 LESS-DN, and 43 multi-port RDN. Continuous variables were compared by one-way analysis of variance, with Tukey-adjusted post-hoc comparisons where appropriate; categorical variables were compared using chi-square testing. The Xi SP + 1 RDN technique used a 4–5 cm periumbilical GelPort containing the camera/working access and a 12-mm AirSeal assistant port, plus one upper quadrant 8-mm robotic port. Results Mean age was 36.5 ± 9.6 years in SP + 1 RDN, 33.4 ± 8.1 years in LESS-DN, and 34.7 ± 8.9 years in Multi-port RDN (P=.012). BMI was similar among groups (P=.378). Mean warm ischaemia time was 4.36 ± 1.24, 3.53 ± 1.02, and 4.05 ± 1.08 minutes, respectively (P<.001). Mean operative time was 178.1 ± 28.5 minutes for SP + 1 RDN, 193.0 ± 51.8 minutes for LESS-DN, and 254.8 ± 45.5 minutes for Multi-port RDN (P<.001). Median length of stay was 2 days in all groups. All 59 SP + 1 RDN procedures were completed robotically without transfusion or conversion; one intraoperative bleeding episode was controlled robotically. Conclusions Reduced-port SP + 1 RDN donor nephrectomy using the da Vinci Xi platform is feasible and preserves short warm ischaemia time and a reasonably short operative time compared with the centre’s earlier multi-port robotic experience. The approach should be regarded as an Xi-based reduced-port configuration—not as da Vinci SP surgery. Its principal practical advantage is the ability to pursue port reduction while retaining triangulation, assistant access, and existing Xi infrastructure.
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: green
OpenAlex ID: W7225891418
Cites: 46
Cited by:
Related to: 10