Work

Mooney Viscosity from Steady-Shear Measurements in a Rubber Process Analyzer

Year: 2026
Type: preprint
Abstract: The Mooney viscosity ML(1+4) is still the most widely used flow parameter of unvulcanized rubbers, although it is a torque and not a viscosity. This work derives the relation between the Mooney torque and the steady-shear viscosity. An analytical solution for the rotor faces and the annular gap, corrected numerically for the corners, gives a conversion factor U(n), which depends only weakly on the flow index n. At a representative shear rate of about 1.2 s −1 , the Mooney viscosity is, therefore, proportional to the viscosity. The relation was checked against steady-shear flow curves measured in a rubber process analyzer (RPA) on filled compounds, EPDM raw polymers and natural rubbers. On average, the measured Mooney viscosity is 1.23 times the calculated one, with a scatter of about 8 %. Thirteen industrial compounds from a second laboratory confirm this empirical factor without adjustment. With ML ≈ 0.90 η(1.2 s −1 )/(kPa s), the Mooney viscosity is predicted within the reproducibility of the Mooney test. The cause of the factor remains open; elastic effects at the edge of the rotor are a possible explanation. A closed-cavity rheometer which is able to measure in steady rotation, and not only in oscillation, can thus provide the Mooney viscosity for quality control in addition to cure kinetics and flow curves, which are needed for the description of processes such as injection molding, compression molding and extrusion.
Source: ChemRxiv
Language: English
Open Access status: green
OpenAlex ID: W7225897483
Cites:
Cited by:
Related to: 10