Work

A Computational Based Platform for the Design of [PtCl₆]²⁻ Anion Receptors

Year: 2026
Type: article
Abstract: This poster was presented at the CHPC National Conference 2023 (Centre for High Performance Computing, South Africa). It describes an automated multilevel computational workflow for designing and evaluating anion receptors for the hexachloroplatinate(IV) anion, [PtCl₆]²⁻, in water. Background. Computational chemistry is still not reliable for designing anion receptors a priori when they have to work in highly polar solvents such as water. This matters for platinum group metal (PGM) refining. There, [PtCl₆]²⁻ has to be recovered selectively from strongly acidic, high-chloride process streams that also contain many competing metal chlorido complexes. Experimental receptor development usually runs as a slow loop of design, synthesis and evaluation by solvent extraction (SX) or column studies, and it often ends at a sub-optimal result. Methodology. Triethylenetetramine (trien) and its derivatives were used as a case study. Using the CREST and CENSO algorithms with the ORCA quantum chemistry package, the workflow screens conformer ensembles for systems of about 100–200 atoms in a funnel of stages: Constrained conformer sampling with DFT single-point energies Constrained, then unconstrained, DFT optimisations DLPNO-CCSD(T) single-point energies Final free energies The workflow combines r²SCAN-3c electronic energies, GFN2-xTB/ALPB/SPH thermostatistical contributions, and continuum solvation (ALPB, COSMO-RS). It computes conformational equilibria, pKₐ values, solvation free energies, and interaction enthalpies and entropies. Complexation is broken down as ΔG_f^calc = ΔG_b^gas + ΔG_def + ΣΔG^solv, which separates gas-phase binding, ligand preorganisation (deformation) and solvation. Calculations ran in parallel on the CHPC Lengau cluster (24 cores, 40 GB memory per job). Results. Computed stepwise protonation constants of the trien ligand match isothermal titration calorimetry (ITC) data closely: Step Computed pKₐ ITC pKₐ 1 10.19 10.37 2 10.06 10.00 3 7.65 7.70 4 4.15 4.49 The computed free energy for forming [(H₄L)PtCl₆]²⁺ is −14.7 kJ/mol, compared with −17.8 kJ/mol from experiment. Key finding. Many anion receptor design strategies emphasise preorganisation. For this system, however, the solvation free energy of the anion–ligand complex outweighs the free energy of ligand preorganisation. This points to solvation as a central design parameter for PGM-selective receptors in water. Acknowledgements. Computational resources were provided by the Centre for High Performance Computing (CHPC), part of the National Integrated Cyberinfrastructure System (NICIS), South Africa
Language: English
Open Access status: green
OpenAlex ID: W7225905953
FWCI:
Cites:
Cited by:
Related to: 10