An Alkali-Metal Thermal Converter Coupled to a Fission Heat Source for an Outer-Planet Orbiter: Efficiency Between Its Temperatures, Radiator Sizing and Specific Mass

Year: 2026
Type: article
Abstract: This paper presents a design study of a system whose operating principle is Alkali-metal thermal-to-electric conversion (sodium heat-pipe AMTEC) from fission heat. The sizing is computed from stated assumptions, with every headline quantity produced by the deposited calculation script. The headline results are: electrical kW = 25.5; carnot = 0.545; radiator m2 = 23; specific power W per kg = 22.1. The study is simulated and computed, not measured, and the design is labelled SIMULATED, NOT MEASURED. Where the computed outcome is unfavourable to the concept, that outcome is stated as the result rather than softened: the purpose of the study is to establish, from the governing relations, what a system of this kind can deliver at the stated distance, temperature, or scale, what it costs in mass, area or power, and which assumption controls the answer.
Language: English
Field: Energy
Open Access status: green
OpenAlex ID: W7225914016
FWCI: 3.094
Cites:
Cited by: 1
Related to: 10