Year: 2026
Type: article
Abstract: Key Takeaways Trenchless cured‐in‐place pipe (CIPP) offers a less disruptive, cost‐effective alternative to open‐cut water main replacement. DC Water implemented a rigorous air quality monitoring and testing plan to address regulatory and community concerns. Monitoring during nonstyrene epoxy CIPP installation confirmed that volatile organic compound concentrations remained below health‐based exposure limits. Air monitoring and emission testing can strengthen regulatory confidence and inform industry best practices.
Source: American Water Works Association
DOI: 10.1002/awwa.70174
Authors: Burak Kaynak, William Elledge
Language: English
Subfield: Health, Toxicology and Mutagenesis
Field: Environmental Science
Domain: Physical Sciences
Open Access status: bronze
Funder: University of Texas at Arlington
OpenAlex ID: W7225984666