Respiratory frequency does not track perceived fatigue independently of time-on-task during a half-marathon: a wearable-sensor field study

Year: 2026
Type: preprint
Study design: Observational Study
Abstract: Breathing pattern is suggested to reflect physical load and stress, but field evidence is limited. This study examined whether breathing pattern, measured with a wearable sensor shirt, tracks perceived fatigue during a half-marathon. Fifteen recreational runners (12 analyzed) completed a 21.1 km time trial while ratings of fatigue (ROF) were recorded every 5 min. Respiratory frequency ( f R ) increased + 7.9 ± 6.8 breaths/min between the first and last quarters of the run, ribcage contribution to breathing increased by about 25% from seated rest to peak, and thoraco-abdominal coordination averaged − 16.6 degrees (-4.6 to -34.3; abdomen precedes thorax). Runners performed locomotor-respiratory coupling (LRC) for 47.1 ± 26.0% of the run, most commonly at a 4:1 step-to-breath ratio. f R was strongly correlated with ROF (ρ = 0.71), but this association disappeared after adjusting for time-on-task (ρ = 0.11, 95% CI − 0.08–0.29). Physiological variables did not classify ROF better than the majority-class baseline, but time-on-task did, and runners differed substantially in how their breathing pattern tracked fatigue. Because perceived fatigue and respiratory frequency both increase with time during a continuous self-paced run, their association cannot be separated from time-on-task in such protocols. Future field studies should use designs that dissociate fatigue from elapsed time.