Work

An in-vitro comparison of microbial adhesion on 3M stainless steel and preformed bioflx crowns: A pilot study

Year: 2026
Type: article
Abstract: Introduction : Restoring primary teeth requires dental materials that demonstrate favorable clinical properties and low bacterial adhesion and colonization of Streptococcus Mutans (S. Mutans) and other harmful bacteria. Assessing and comparing the microbial adherence on 3M stainless steel and prefabricated BioFlx crowns in primary molars is the study's goal. Materials and Methods : 20 specimens in two groups—3M Stainless Steel crown [SSC] and prefabricated BioFlx crown—were exposed to a bacterial suspension of S. Mutans (1x106 CFU/mL) for this in vitro experimental investigation. The total number of S. Mutans was counted and expressed in colony forming units (CFU) after the specimens were incubated on Mitis salivarius bacitracin agar. Results : A statistically significant difference in the microbial count between the preformed BioFlx crowns and the 3M SSC was observed. Conclusion : The results of this study indicate that BioFlx crowns exhibited lower S. mutans adhesion than 3M stainless steel crowns under the experimental conditions tested. Further studies are required to determine whether these findings translate into clinically relevant differences in plaque accumulation and restoration performance.
Language: English
Field: Dentistry
Open Access status: diamond
OpenAlex ID: W7226019502
FWCI:
Cites: 13
Cited by:
Related to: 10