Work

A Vapour-Compression Heat Pump Drawing on Subsurface Warmth for Lunar Night Habitat Heating

Year: 2026
Type: article
Abstract: This study sizes a vapour-compression heat pump delivering 12 kilowatts of habitat heat through the lunar night from a subsurface source at 240 kelvin: the Carnot coefficient of performance is 5.36, the working coefficient at the stated second-law efficiency is 2.41, electrical demand is 4.97 kilowatts and ground extraction is 7.0 kilowatts. Sizing follows from computed thermal budgets derived in the study. This is a computed study with no targeting or weapon application. The work is simulated and computed from stated assumptions, not measured.
Language: English
Open Access status: green
OpenAlex ID: W7226025849
FWCI: 1.577
Cites:
Cited by: 1
Related to: 10