Abstract: BACKGROUNDConcomitant femoral head and neck fractures with subtrochanteric extension are rare and biomechanically demanding injuries involving both the intracapsular and extracapsular regions.Owing to their rarity, the optimal fixation strategy has not yet been standardized. CASE SUMMARYA 29-year-old male sustained a displaced femoral head and neck fracture with subtrochanteric extension following a high-energy motor vehicle collision.After initial stabilization and computed tomography imaging, a head-preserving dual-implant fixation strategy was employed using three 7.0 mm cannulated screws for the neck component and a lateral hook plate for the subtrochanteric extension.At the 2-week follow-up, the surgical wound had healed well, and radiographs demonstrated stable anatomical alignment without hardware failure or loss of reduction. CONCLUSIONDual-implant fixation is a feasible method for managing these complex fractures in young adult patients, providing stable fixation while preserving the femoral head.Long-term monitoring and follow-up are essential to assess fracture union and complications, particularly avascular necrosis.