Work

Optimal signal combinations for automatic sleep assessment and respiratory event detection

Year: 2026
Type: dissertation
Abstract: Polysomnography (PSG) is the clinical standard for sleep assessment, including sleep staging and the diagnosis of sleep disorders.PSG provides a comprehensive overview of physiological activity by simultaneously capturing a wide range of signals.The procedure requires careful placement of multiple electrodes on the scalp, face, chest, and limbs, as well as several other sensors, by trained technicians.This can be uncomfortable for patients and may alter natural sleep patterns or contribute to fragmented sleep.In addition, PSG is conducted in specialized sleep laboratories, which can be unfamiliar and disruptive for many individuals.These practical challenges limit the scalability of PSG and result in a substantial number of patients remaining unevaluated, particularly in healthcare systems with rising demand for sleep evaluations.Although PSG offers rich physiological information, not all recorded signals may be equally essential for accurate sleep staging or respiratory event detection.This has raised important questions about whether the complexity of the measurement setup can be reduced without compromising diagnostic performance.Among the various signals recorded during PSG, electroencephalography (EEG) is the key signal used to identify sleep stages.PSG is complemented by electrooculography (EOG) and electromyography (EMG), which help distinguish eye movements and muscle tone.In standard PSG, six EEG channels are recorded from frontal, central, and occipital regions of both left and right brain hemispheres.However, using multiple EEG channels increases the complexity of the setup.In addition, PSG includes multiple II respiratory-related signals, including nasal pressure, thermistor airflow, thoracic and abdominal effort, and blood oxygen saturation (SpO₂), which are used to diagnose obstructive sleep apnea (OSA).OSA is a common and clinically significant sleep disorder, and its severity is determined by the apnea-hypopnea index (AHI), computed by the number of respiratory events per hour during sleep.Overall, sleep staging and OSA diagnosis are traditionally performed through manual inspection of multiple physiological signals.However, manual scoring is time-consuming and prone to inter-and intra-scorer variability.These limitations have motivated a growing interest in simplified and more automated sleep monitoring solutions.This thesis aimed to address shortcomings in sleep staging and OSA assessment originating from their complex measurement setup.For sleep staging, we examined EEG and EOG signals from both hemispheres to determine whether distinguishable patterns existed in the signal characteristics across hemispheres.We also investigated various EEG and EOG signal combinations in the training of a deep learning model to identify the most effective signals or signal sets for automatic sleep staging.For respiratory event detection and OSA severity assessment, we evaluated all possible combinations of commonly used signals (i.e., nasal pressure, SpO₂, photoplethysmography (PPG), thermistor, and thoracic and abdominal effort), each trained using a deep learning model, to determine the optimal signal configurations.This thesis revealed that interhemispheric differences in EEG and EOG signal features were negligible, indicating that the left and right hemispheres provide comparable technical information for sleep staging.Moreover, similar sleep staging performances were achieved with various EEG and EOG signal configurations (i.e., F1-score: Wake = 0.86-0.91,N1 = 0.39-0.55,N2 = 0.78-0.85,N3 = 0.74-0.84,and REM = 0.85-0.92;κ-value = 0.70-0.79).This indicates that accurate automatic sleep staging can be maintained even with reduced signal sets.In addition, configurations with nasal pressure signal achieved the highest performance in automatic respiratory event detection (κ-values > 0.60 in the second-by-second analysis) and in the OSA severity estimation (κ-values > 0.48 in AHI estimation).PPG and SpO₂ configurations III yielded slightly lower performance (κ-values = 0.49 in the second-by-second analysis; κ-values = 0.34 for AHI estimation) but were identified as having potential for OSA screening purposes.In conclusion, this thesis provides technical evidence that simplified signal configurations can support reliable and accurate sleep assessment.The negligible interhemispheric differences in EEG and EOG features demonstrate that one hemisphere provides enough information for sleep staging, and the relatively similar performance across all EEG and EOG configurations further reinforces this simplification for automatic sleep staging.Moreover, our findings demonstrate that nasal pressure is a crucial signal for accurate respiratory event detection and OSA severity assessment.The PPG and SpO₂ configuration, on the other hand, offers a practical alternative for screening of OSA, even though their ability to locate individual breathing cessations in a second-by-second manner was low.Overall, the results of this thesis provide technical support for simplifying the measurement setup without significantly compromising diagnostic performance, thereby advancing the development of more accessible, userfriendly, and scalable sleep assessment systems.
Language: English
Open Access status: green
OpenAlex ID: W7226044903
Cites: 215
Cited by:
Related to: 10