Abstract: This paper computes a wildfire budget for a mature conifer stand with a canopy base height of six metres and foliar moisture near ninety percent, using published observations as inputs and standard relations stated in full. The principal computed quantities are: canopy base height m = 6; foliar moisture percent = 90; critical surface intensity kW per m = 2167; available surface intensity kW per m = 5729; margin ratio available over critical = 2.644; surface rate of spread m per s = 0.22. Each value is derived in the deposited code from the stated inputs, so the budget can be re-run with alternative published values. The results place this fire or fuel system quantitatively alongside other events treated with the same relations, and the discussion identifies which input dominates the uncertainty of each headline number. Computed from stated assumptions and published data, not a new measurement.