Work

Multicenter evaluation of concordance between AI-assisted and hybrid AI-assisted cervical imaging systems and visual inspection with acetic acid in community-based cervical precancer screening

Year: 2026
Type: article
Study design: Observational Study
Abstract: Background Visual Inspection With Acetic Acid (VIA) remains widely used for cervical precancer screening in low- and middle-income countries but is subject to operator-dependent variability. AI-assisted cervical imaging may improve consistency, although its performance across heterogeneous real-world settings remains insufficiently characterized. This study evaluated the concordance of AI-assisted and hybrid AI-assisted cervical imaging systems with routine VIA across multiple screening facilities. Methods This multicenter cross-sectional study included 253 women undergoing cervical screening at four facilities in West Java, Indonesia, between October 2025 and January 2026. VIA was used as the operational comparator rather than a histopathological reference standard. Cervical images obtained before and after acetic acid application were assessed using an automated AI-assisted system and a hybrid workflow involving expert review. Results were dichotomized as positive or negative. Concordance was assessed using Cohen’s kappa, with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall agreement calculated relative to VIA. Results Twenty-three participants (9.1%) were VIA-positive. The AI-assisted system showed 56.5% sensitivity (95% CI, 34.5–76.8), 92.2% specificity (95% CI, 87.9–95.3), 41.9% PPV, and 95.5% NPV, with 88.9% overall agreement and moderate concordance (κ = 0.421; 95% CI, 0.266–0.622). The hybrid system showed 21.7% sensitivity (95% CI, 7.5–43.7), 95.7% specificity (95% CI, 92.1–97.9), 33.3% PPV, and 92.4% NPV, with 88.9% agreement and fair concordance (κ = 0.206; 95% CI, 0.014–0.398). Site-specific agreement varied but was limited by sparse VIA-positive cases. Conclusion Both AI-assisted workflows demonstrated high specificity and NPV but limited sensitivity relative to routine VIA. Findings highlight the variability of AI-assisted screening across real-world settings and the importance of standardized image acquisition. Histopathological validation is required to establish diagnostic accuracy and clinical utility.
Language: English
Subfield: Epidemiology
Field: Medicine
Open Access status: gold
Estimated APC paid: $3,090
OpenAlex ID: W7228389382
FWCI:
Cites:
Cited by:
Related to: 10