Work

Effect of Ventilated Façade on Thermal Comfort in University Laboratories

Year: 2026
Type: article
Abstract: The most effective technique for achieving sustainable building is the use of ventilated façades. Achieving thermal comfort in university laboratories and other facilities requires ensuring that building occupants feel comfortable and satisfied, as this has a direct impact on students' performance. The research aims to investigate the effect of applying ventilated façades, with variable distances from the main façade, on thermal comfort in a laboratory at the University of Mosul, Iraq, under the hot dry climate with hot summers and cold winters, to maximize the ventilated façade's performance. The research uses a simulation method with IES-VE, comparing opaque and perforated ventilated façades. The study evaluates (Predicted Mean Vote) PMV, (Predicted Percentage of Dissatisfied) PPD, Comfort Index, and the number of uncomfortable people for each façade. The results show that using a ventilated façade enhances thermal comfort in Summer, Autumn, and Spring. The study demonstrates that a perforated ventilated façade with a 0.10m air cavity significantly optimizes thermal comfort, offering a sustainable design strategy for educational facilities in arid regions
Institution: University of Mosul
Language: English
Open Access status: diamond
OpenAlex ID: W7229748628
FWCI:
Cites: 17
Cited by:
Related to: 10