The Tymewear Tidal/Tv ratio is not a constant: sessions, step ramps and signal dropouts in three cyclists
Year: 2026
Type: preprint
Study design: Case Report
Abstract: Purpose. The Tymewear VitalPro reports tidal volume (Tidal) and minute ventilation in arbitrary units (AU) and proposes to guide training from minute ventilation thresholds entered in the bike computer. This model assumes that an athlete's AU / litre relation stays stable. We examined this assumption retrospectively in three cyclists. Methods. Three case studies (one woman), five sessions (four indoor, one on the road). The Tymewear was worn together with a VO₂ Master Pro (reference: Tv in litres, breathing frequency RF). Recordings were synchronised on heart rate and power. The Tidal/Tv ratio (AU/L) and RF agreement were computed over 1-min windows. Results. (1) Outside dropouts, RF measurement agreed with the reference (bias −0.43 to +0.24 br/min, limits of agreement ±0.53 to ±1.92 br/min; pooled Bland-Altman over 161 windows: bias −0.01 br/min, limits of agreement ±1.25 br/min). Dropouts affected 10 of 171 windows (6%); with all windows included, the limits reached ±5.92 br/min. (2) In case A, at the same power and the same route, the ratio was 13% higher in the second session, and the cause could not be isolated (day, strap placement, position in the session, reference mask). (3) With the strap left untouched, the step ramp gave a higher ratio than the constant-power bouts of the same session in two athletes (case A +22%, case B +9%), including at equal RF; the difference in case C (+5%) was not distinct from variability. (4) Along constant-route ramps, the ratio fell in two athletes (−12% and −18%) and rose in the third (+18%); at constant power, it varied little from one intensity to another (1 to 6%). (5) In two athletes, the signal dropped out for at least 2 and 6 min with no quality indicator in the recorded data: RF off by 3 to 10 br/min, ratio from +32% to −62% of its stable value. (6) The ratio was higher with nasal than with oral breathing in both comparisons at similar power, but the case A difference is fully predicted by RF; the route is not isolated. Conclusion. Outside dropouts, RF was measured reliably. Absolute Tidal and minute ventilation values did not carry over from one session to another in the same athlete, nor from a step ramp to constant-power bouts, nor along a ramp. Thresholds in AU should not be reused from one session or protocol to another without checking. Observations in three cases; mechanisms not tested. The deposit contains the English and French versions (PDF and Word), each with five figures and an appendix listing the 161 retained 1-min windows. Part of the VST Research Series (Ventilatory Strategies Training), HNS Performance. Not peer reviewed.
Author: RICCI, Cyril
Language: English
Subfield: Physiology (medical)
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7233224857