Abstract: This paper recomputes the principal source budgets of Advanced Photon Source Upgrade from its published headline parameters: a beam energy of 6.0 GeV, a stored current of 0.2 A, a circumference of 1104.0 m and a dipole field of 0.5 T. The bending radius implied by those inputs is 40.03 m, giving a critical energy of 11.97 keV against a published value of 12.0 keV, an energy loss per turn of 2864 keV and a total radiated power of 573 kW against 570.0 kW published. A reference undulator of 2.5 cm period and 1.1 T peak field has parameter K of 2.57 and a fundamental at 3.18 keV, with the third and fifth harmonics reaching 9.5 keV and 15.9 keV. At the reference wavelength of 0.5 nm the diffraction-limited emittance is 39.8 pm rad, so the stored beam, with a horizontal emittance of 41.7 pm rad, carries a coherent fraction of about 0.954. Computed and published values agree at the level expected once lattice averages and insertion-device loads are accounted for, which makes the published parameter set an internally consistent basis for planning experiments at this facility.