Early Detection of Cooling Fan Failure in a 200 kW Boiler Draft Fan Motor: A Real Case Study from a Petroleum Facility in Egypt
Year: 2026
Type: preprint
Abstract: This paper presents a real case study of a 200 kW Siemens induction motor (1LA6 317-4AA60) driving a boiler draft fan in a petroleum facility in Egypt. On 8 November, temperature reached 99°C at Drive End and Motor Body, and 64°C at Non-Drive End. Inspection revealed a crack in the motor cooling fan. After approval from Operations, the fan was replaced on 9 November. Post-repair monitoring from 18:10 to 05:00 showed temperature stabilized at 41-55°C. Reduction: D -49.5°C, M -57.7°C, ND -36.7°C. This case proves temperature trend monitoring can prevent catastrophic failure of an Ex nA II T3 motor and prevent boiler shutdown.
Author: Mostafa, Mohamed Magdy sayed
Language: English
Subfield: Control and Systems Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7233548830
Cites:
Cited by:
Related to:
