Establishment of local diagnostic reference levels for adult and pediatric computed tomography examinations in two tertiary hospitals in Taif, Saudi Arabia
Year: 2026
Type: article
Study design: Observational Study
Abstract: Background Computed tomography (CT) substantially increases radiation exposure from diagnostic imaging, hence monitoring patient dose is important. In clinical practice, diagnostic reference levels (DRLs) are important as a benchmark for spotting exceptionally high or low dose levels. Objectives To establish local diagnostic reference levels (DRLs) for the most common pediatric and adult CT examinations conducted at two tertiary care hospitals in Taif, Saudi Arabia, and to compare the established local DRLs with published Saudi and international DRLs. Methods Retrospective review of CT scans from King Abdulaziz Specialist Hospital (KAASH) and King Faisal Medical Complex (KFMC) in Taif. CT examination data covering January 2024 to December 2025 were retrospectively retrieved from the Radiology Information System (RIS) and Picture Archiving and Communication System (PACS) of the participating hospitals A total of 6451 examinations were included, comprising 550 pediatric and 5901 adult examinations. Local patient-level DRL75 estimates were derived as the 75th percentile of the individual-examination CTDIvol and DLP distributions. Results Dose metrics differed by age, anatomical region, and facility. Adult head CT had the greatest DLP DRL75 982.53 mGy cm at KFMC and 831.00 mGy cm at KAASH. Children had higher CTDIvol and DLP values on head CT examination compared to chest and abdominal exams. There was considerable inter-hospital variation in some examination categories. Comparisons with national and international reference levels showed variable degrees of concordance with some local results approaching or exceeding stated reference levels. Conclusion The derived local patient-level DRL75 estimates provide benchmarks for CT dose monitoring and optimization. Between hospital and age heterogeneity underlines the need for standardization of protocols, continuing dose monitoring and regular assessment of DRLs, particularly in pediatric CT.
Authors: Hamid Osman(Conceptualization, Funding acquisition, Project administration, Supervision, Validation, Writing – review & editing), Mayeen Uddin Khandaker(Funding acquisition, Project administration, Resources, Software, Writing – original draft, Writing – review & editing), Meznah Alharthi(Data curation, Formal analysis, Investigation, Writing – original draft), Raghad Alotaibi(Data curation, Formal analysis, Investigation, Writing – original draft), Maha Alwathnani(Data curation, Formal analysis, Funding acquisition, Methodology, Writing – original draft), Batool Althagafi(Data curation, Formal analysis, Methodology, Validation), Sahal Alotaibi(Methodology, Supervision, Validation), Abdullah Mohammed Metebi(Data curation, Formal analysis, Investigation, Writing – original draft), Mohammed Asiri(Data curation, Formal analysis, Investigation, Writing – original draft), Ali Fehid Algarni(Data curation, Formal analysis, Investigation, Visualization, Writing – original draft)
Language: English
Topic: Radiation Dose and Imaging
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $1,400
Funder: Taif University
OpenAlex ID: W7233569834
