Rayleigh Collapse Time for a Millimetre Cavity in Water: Inertial Timescale, Wall Speed and Rebound Radius Budgets

Year: 2026
Type: article
Abstract: Rayleigh collapse time for a millimetre cavity in water is examined for a vapour cavity of initial radius one millimetre in water at twenty degrees Celsius, driven by a one-bar pressure difference. Principal computed quantities: driving pressure Pa = 98,986.0; collapse time us = 91.88; wall speed at half radius m s = 21.51; wall speed at tenth radius m s = 257.0; rayleigh energy uJ = 414.6; rebound radius um = 493.2. The governing idea, for vapour cavity of initial radius one millimetre in water at twenty degrees Celsius, runs as follows. An empty spherical cavity in an incompressible liquid collapses in the rayleigh time, which scales with initial radius and the square root of liquid density over driving pressure; viscosity, surface tension and gas content enter only as corrections at this size. Setting driving pressure Pa at 98,986.0 beside collapse time us at 91.88 shows, for vapour cavity of initial radius one millimetre in water at twenty degrees Celsius, the scale, for vapour cavity of initial radius one millimetre in water at twenty degrees Celsius, before interpretation. Both numbers, for vapour cavity of initial radius one millimetre in water at twenty degrees Celsius, come from the rayleigh collapse time for a millimetre cavity in water relations. The later discussion, for vapour cavity of initial radius one millimetre in water at twenty degrees Celsius, sets driving pressure Pa at 98,986.0 against published values for vapour cavity of initial radius one millimetre in water at twenty degrees Celsius and names, for vapour cavity of initial radius one millimetre in water at twenty degrees Celsius, the input moving driving pressure Pa at 98,986.0 furthest.
Language: English
Open Access status: green
OpenAlex ID: W7233589565
FWCI:
Cites:
Cited by:
Related to: