Work

Yttrium Iron Garnet: Gilbert Damping, Frequency-Dependent Linewidth, Magnon Lifetime and Resonance Quality

Year: 2026
Type: article
Abstract: Yttrium iron garnet owes its central place in magnonics to a Gilbert damping parameter that can fall to the 10^-4 range in films and lower in polished spheres, giving resonance linewidths under one oersted and magnon lifetimes of hundreds of nanoseconds at microwave frequencies. Gilbert damping makes the field-swept linewidth grow linearly with frequency, with slope set by twice the damping parameter divided by the gyromagnetic ratio, on top of a frequency-independent inhomogeneous offset; the same parameter fixes the magnon lifetime as the inverse of damping times angular frequency and the resonance quality factor as its reciprocal combination. Headline values are gilbert linewidth at 10ghz mt garnet = 0.09143; gilbert linewidth at 10ghz oe garnet = 0.9143; gilbert frequency linewidth at 10ghz mhz garnet = 2; gilbert magnon lifetime at 10ghz ns garnet = 159.2; gilbert quality factor at 10ghz garnet = 5000; gilbert linewidth at 2ghz mt garnet = 0.03429. Slope and intercept are quoted separately, because they indict different culprits, growth quality in one case and uniformity in the other.
Language: English
Open Access status: green
OpenAlex ID: W7233598447
FWCI:
Cites:
Cited by:
Related to: