Work

Postoperative evaluation of Achilles tendon using short echo time MRI and artificial intelligence

Year: 2026
Type: article
Abstract: The objective was to identify the optimal MRI sequence to evaluate postoperative Achilles tendon (AT) healing. We compared T2 gradient sequence with 4.1ms (TE4) and 16ms (TE16) echo time with PD (proton density-weighted) through signal intensity (SI) measurements and correlated them with tendon-specific biomarkers. Additionally, the study assessed agreement between radiologists and AI in evaluating tendon-specific biomarkers. A total of 45 patients (mean age 36 ± 6 years; 36 men, 9 women) underwent nine consecutive MRI examinations at intervals from 1 to 52 weeks after surgery. SI in all postoperative MRI examinations was measured in AT in TE4, TE16 and PD. SI in the operated AT appears normal in PD and TE16 sequences around week 39. However, TE4 still shows high signals, indicating ongoing remodeling. Significant correlations were found between biomarkers and SI in the TE4 sequence ( p < 0.001 for structural changes and tendon edema, and p = 0.002 for tissue edema). High SI values were associated with poor biomarker outcomes. The mean absolute errors (MAE) between AI model scores, obtained using only axial TE4 scans, and radiologist evaluations ranged from 0.12 to 0.63. In conclusion, TE4 demonstrated greater sensitivity to persistent postoperative signal and structural abnormalities and may be useful in postoperative assessment of AT. AI scores showed relatively small absolute differences from the reference radiologist scores.
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $2,690
OpenAlex ID: W7233613015
FWCI:
Cites: 6
Cited by:
Related to: